Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Dental press j. orthod. (Impr.) ; 16(4): 41.e1-41.e6, jul.-ago. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-604323

ABSTRACT

OBJETIVO: o objetivo deste estudo foi verificar a fricção no braquete (Roth, Composite, 10.17.005, 3,2mm, largura 0,022" x 0,030", Torque -2° e angulação +13°, Morelli®, Brasil), utilizando fios ortodônticos retangulares de 0,019" x 0,025" de aço inoxidável (Morelli®, Brasil) e de níquel-titânio superelásticos Bioforce com IonGuard e sem IonGuard (Bioforce, GAC®, EUA). MÉTODOS: foram utilizados 24 conjuntos braquetes/segmento de fio, divididos em 3 grupos de acordo com o fio. Cada conjunto braquete/segmento de fio foi testado 3 vezes e obtida uma média. Os ensaios foram realizados em máquina universal de ensaios EMIC DL2000®. Os dados foram submetidos à Análise de Variância com significância de 95 por cento. RESULTADOS: o fio retangular Bioforce com IonGuard apresentou fricção significativamente menor que o Bioforce sem IonGuard, porém sem diferença do fio de aço inoxidável. Entretanto, o coeficiente de variação dos fios Bioforce com e sem IonGuard foi menor que o do fio de aço inoxidável. CONCLUSÃO: os fios retangulares de 0,019" x 0,025" Bioforce com IonGuard apresentam menor fricção que o fio Bioforce sem IonGuard, sem diferença para o fio de aço inoxidável.


OBJECTIVE: The aim of this study was to evaluate the friction forces on brackets (Roth, Composite, 10.17.005, 3.2 mm, width 0.022" x 0.030 ", Torque -2° and angulation +13°, Morelli®, Brazil), with stainless steel orthodontic rectangular wire (Morelli®, Brazil) and nickel titanium superelastic Bioforce wires with and without IonGuard (Bioforce, GAC®, USA). MATERIAL AND METHODS: Twenty-four brackets/wire segment combinations were used, distributed into three groups according to the orthodontic wire. Each bracket/wire segment combination was tested three times. The tests were performed in a universal testing machine Emic DL2000®. The data was submitted to ANOVA one way followed by Tukey's post hoc test (p<0.05). RESULTS: The rectangular orthodontic Bioforce wire with IonGuard presented significantly lower resistance to sliding than Bioforce without IonGuard. There was no statistical difference among the other groups. However, the coefficient of variation of Bioforce with and without IonGuard was lower than that of the stainless steel wire. CONCLUSION: The rectangular orthodontic Bioforce wire with IonGuard presented lower resistance to sliding than Bioforce without IonGuard, with no difference to the stainless steel wire.


Subject(s)
Friction , Orthodontic Appliances , Orthodontic Brackets , Orthodontic Wires , Orthodontics
2.
RGO (Porto Alegre) ; 53(4): 329-334, out.-dez. 2005. ilus
Article in Portuguese | LILACS, BBO | ID: lil-436249

ABSTRACT

Os autores relatam o caso clínico de um indivíduo de 09 anos, gênero masculino, com dor provocada no elemento 45, que apresentava-se estruturalmente displásico. Ao exame radiográfico, uma formação radicular inadequada com hipótese de diagnóstico de DENTE DE TURNER. Para facilitar a reconstrução dentária, uma ulectomia à laser foi realizada e posteriormente, a reconstrução direta em resina composta fotopolimerizável, devolvendo a forma anatômica e melhoria das funções. O tratamento utilizado proporcionou a preservação da estrutura dentária além de diminuir a sensibilidade dentária, tempo operatório e melhorar a estética.


Subject(s)
Humans , Male , Child , Dental Enamel Hypoplasia/diagnosis , Dental Enamel Hypoplasia/therapy